AKUS-SD COMBI which is composed of only one board is the new designed of AKUS-SD Emergency Rescue Unit. It provides all features of AKUS-SD. |
 |
In case of mains failure it moves the lift which stopped between two floors to floor level, opens the automatic door and passengers are evacuated in safety. |
 |
For lifts with automatic door, if mains failure occurs at floor level, door is opened and passengers are evacuated. |
 |
Can be applied to all one speed, two speed or speed-controlled systems. |
 |
Suitable for asynchronous drives. |
 |
Works open loop. No need to put a sensor on the motor. |
 |
Includes an internal transformer. |
 |
Gets the power from 5 pcs batteries which need no maintenance. |
 |
Thanks to smart battery charge system which does not tire the batteries and makes them work for many years. |
 |
Because it is integrated into control panel, all the connections necessary for emergency unit is done in fabric. So the setup time is minimized. |
 |
No safety circuit connection is needed. Safety circuit connection is only made to lift controller. |
 |
Can be disabled with a few cable connection in case of failure. |
 |
The starting delay of rescue operation can be adjusted for buildings have diesel generators. |
 |
With LCD program parameters like: max travel time, automatic door type, motor drive frequency, door opening time, starting delay, language e.tc. can be adjusted easily. |
 |
Lift monitoring and error reporting with user-friendly menu interface. |
 |
Turkish, English language menu options. |
 |
Designed according to EN81-1. |